STP-200/300/400 Series Instruction Manual
10
5
4
3
2
1
0.5
10 20 30 40
Ambient Temperatures (
℃
)
Life of the Internal Battery (Year)
40
5
2
Allowable Shelf Life of the Internal Battery (Month)
50
20
30
10
10 20 30 40
Ambient Temperatures (
℃
)
Figure 9.2 Allowable Shelf Life
of the Internal Battery
Figure 9.1 Life of the Internal Battery
9.3 How to Charge the Internal Battery
The battery is charged while the power is "ON," regardless of the operation
state of the STP pump.
After a power failure, charge the battery for approx. 12 times the BATTERY
BACKUP time. For example, when the BATTERY BACKUP time is 15 minutes,
it takes approx. 3 hours to charge the battery.
If a power failure occurs 2 times within 3 hours, charge the battery for more than
3 hours before starting to operate the STP pump.
9-2