STP-200/300/400 Series Instruction Manual
NEVER use any gas that is not specified as usable in this Manual.
The use of such gas may corrode the STP pump and damage it.
Always check the STP pump has stopped, then turn OFF the primary
power (Switch the breaker "OFF") before proceeding to any of the
following operations. Failure to do so may cause the STP pump to
rotate accidentally, which may injure operators seriously or result in
electric shock.
Connect or disconnect cables;
Connect an external battery;
Perform maintenance and inspections such as replacement of the
internal battery and/or fuses as well as inspections of deposit
and/or the air cooling fan; or
Perform investigations into probable causes and action/measures
taken in the event of occurrence of a problem.
The STP control unit is a heavy product. Always use a crane or the
like when lifting it. Failure to do so may damage your hipbone or
injure you due to occurrence of an accident such as fall.
Install the STP control unit not only by fitting it with the front panel
fitting screws but also by supporting it from the bottom side. Fitting
the STP control unit with the screws only cannot sustain its weight,
and therefore resulting in product damage.
Always use the STP pump, STP control unit and STP connection
cables of the same model name, serial number and cable length,
which are specified on their own name plate. Failure to do so may
result in product damage. If you plan to use the units with the same
model name but different serial numbers and cable length; they must
be adjusted. If the model names are different, they may not be used
even when performing adjustment. In both cases, contact BOC
Edwards.
3