Sharp R-880D Manual de Instruções Página 71

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 70
STP-200/300/400 Series Instruction Manual
Table 6.3 Operations of the STP Pump after a Power Recovery
(during REMOTE OPERATION)
Remote signal input after a
power recovery
Power failure
time
Number of
rotations after
a power
recovery
POWER ON
signal
START
signal
STP pump's operation
after a power recovery
Yes/No Yes Reacceleration
3,000rpm or
more
Yes/No No Deceleration/Stop
Yes No Re-levitation
Yes Yes
Re-levitation,
reacceleration
Approx. 50msec.
or more
Less than
3,000rpm
No Yes/No POWER OFF state
Yes Yes/No Continues as before.
No Yes Reacceleration
3,000rpm or
more
No No Deceleration/Stop
Yes Yes
Re-levitation,
reacceleration
Yes No Re-levitation
Approx. 35msec.
to less than
50msec.
Less than
3,000rpm
No Yes/No POWER OFF state
Less than
approx. 35msec.
Continues as before.
6.1.2 Abnormal State of Magnetic Bearing
When the magnetic bearing does not function normally due to a breakage of the
STP connection cable, disconnection of connectors, or any abnormality/error of
the STP control circuit, the rotor falls on the touch down bearing, and the STP
pump stops.
The "EMERGENCY OPERATION" lamp lights.
When an abnormality/error occurs in the magnetic bearing, check the
STP pump as well as the STP control unit, and contact Service office.