STP-200/300/400 Series Instruction Manual
3.3.2 STP Pump Installation Positions
The STP pump can be installed vertically, horizontally, upside-down and slanted
(See Figure 3.3, "STP Pump Installation Positions").
Vacuum
Equipment
Upside-down
Horizontal
Slanted
Vertical
Figure 3.3 STP Pump Installation Positions
When installing the STP pump in a horizontal or slanted position, it is
recommended to install it so that the direction of the outlet port is on a vertical
or horizontal plane in the direction of the gravity.
This makes it possible to reduce the load on the magnetic bearing and the heat
generated by the STP pump (See Figure 3.4, "Positions of the Outlet Port on the
Horizontally or Slanted Installed STP Pump").
Outlet Port
Outlet Port
Outlet Port
Outlet Port
Direction of Gravity
Figure 3.4 Positions of the Outlet Port on the Horizontally or Slanted Installed STP Pump