STP-200/300/400 Series Instruction Manual
N.O : Normal Open
N.C : Normal Close
REMOTE
N.O OUT
POWER
N.O OUT
N.O OUT
FAILURE
N.O OUT
N.O OUT
N.O OUT
ACCELERATION
N.O OUT
N.O OUT
EMERGENCY
OPERATION
OVER
TEMPERATURE
BATTERY
OPERATION
NORMAL
OPERATION
REMOTE selection state
signal output pins
SW
CR
CR
CR
CR
CR
CR10
CR11
REMOTE CONNECTOR :
Remote Input/Output Signal Connector
BATTERY OPERATION
state signal output pins
OVER TEMPERATURE
state signal output pins
FAILURE state
signal output pins
EMERGENCY OPERATION
state signal output pins
POWER ON state
signal output pins
ACCELERATION state
signal output pins
NORMAL OPERATION
state signal output pins
(5)
(17)
(6)
(18)
(7)
(19)
(8)
(20)
(9)
(21)
(10)
(22)
(11)
(23)
(11)
(24)
Figure 8.2 Remote Output Signal Pins