72 918496/GP0313
d. Perform the “Mandatory Safety
Shutdown Procedure” on page 10.
e. Slide the down-stop lock bar (B)
all the way through holes (C) in
the frame, holes in the lift arm and
holes (D) in the tilt pivot arm.
f. Replace the lock pins (A) into both
ends of the down-stop lock bar
(B).
Important: Down stop lock bar
(B) must pass all the way through
holes (C) in the frame, holes in the
lift arm and holes (D) in the tilt
pivot arm, with spring pins (A) installed in down stop lock bar (B)
on outsides of the frame arm.
Figure 29 – AL 200/300 Series
Lift Arm Down-Stop
A
B
C
D