Checking and Adjusting V-belt Tension
1. Perform the “Mandatory Safety Shutdown Procedure” on page 10.
2. Open the engine cover.
3. Inspect V-belts (R, Fig. 85) for
damage. If damaged, have belts
replaced by your dealer.
4. Press on V-belts (R) mid-way
between pulleys to check deflec-
tion. Belts should deflect no more
than 8 mm (5/16").
5. If deflection is more than 8 mm
(5/16"): Loosen the adjustment
bolt (S) and rotate the alternator
(T) outward until V-belt tension is
correct. Tighten bolt (S) and re-
check V-belt tension.
Air Conditioning V-Belt
Inspect and service the air
conditioning V-belt (X, Fig. 86) the
same as directed in Checking and
Adjusting V-belt Tension.
To adjust the air conditioning V-belt
tension, Loosen the adjustment bolt
(Y) and rotate the air conditioning
compressor (W) downward until V-
belt tension is correct. Tighten bolt
(S) and re-check V-belt tension.