Accessing the Outer and Inner Filter Elements
1. Perform the “Mandatory Safety Shutdown Procedure” on page 10.
2. Open the engine cover.
3. Unlatch the clamps on the air cleaner housing and remove the element cover.
4. Clean any debris from the cover.
Changing the Filter Elements
1. Perform the “Mandatory Safety Shutdown Procedure” on page 10.
2. Carefully remove the outer filter element (F, F i g . 7 8 ). Do not remove the inner
filter element (G) unless it is to be replaced. If the inner filter element will not
be replaced, skip to step 8.
3. Before removing inner filter element (G) from the housing, clean away any
dirt built up in the housing. Leave the inner filter element installed during this
step to prevent debris from entering the engine intake manifold.
4. Remove the inner filter element.
5. Clean dust and debris from housing (E) and cover (C). Leave the inner filter
element installed during this step to prevent debris from entering the engine
intake manifold.
6. Check the inside of the housing for any damage that may interfere with the
elements.
7. Remove the old inner filter element and install the new inner filter element.
8. Reinstall/replace the outer filter element.
9. Latch clamps (D) to secure cove (C).
10. Check the hose connections and be sure they are all clamped and tightened
properly.