Adaptive tuning
Operation
Is the target response reached?
Increase the response setting.
Has vibration or unusual
noise occurred?
Execute or re-execute adaptive
tuning. (Set [Pr. PB01] to "_ _ _ 1".)
Tuning ends automatically after the
predetermined period of time. ([Pr.
PB01] will be "_ _ _ 2" or "_ _ _ 0".)
If assumption fails after tuning is executed at a large vibration or
oscillation, decrease the response setting temporarily down to
the vibration level and execute again.
Has vibration or unusual
noise been resolved?
Decrease the response until vibration
or unusual noise is resolved.
Using the machine analyzer, set the
filter manually.
End
Factor
The response has increased to the machine limit.
The machine is too complicated to provide the
optimum filter.