5. PARAMETERS
5 - 44
5.2.6 Extension setting 3 parameters ([Pr. PF_ _ ])
No. Symbol Name and function
Initial
value
(unit)
Setting
range
PF21 DRT Drive recorder switching time setting
This is used to set a drive recorder switching time.
When a USB communication is cut during using a graph function, the function will be changed
to the drive recorder function after the setting time of this parameter.
When a value from "1" to "32767" is set, it will switch after the setting value.
However, when "0" is set, it will switch after 600 seconds.
When "-1" is set, the drive recorder function is disabled.
0
[s]
-1 to
32767
PF23 OSCL1 Vibration tough drive - Oscillation detection level
This is used to set a filter readjustment sensitivity of [Pr. PB13 Machine resonance
suppression filter 1] and [Pr. PB15 Machine resonance suppression filter 2] while the vibration
tough drive is enabled.
Example: When you set "50" to the parameter, the filter will be readjusted at the time of 50%
or more oscillation level.
50
[%]
0 to 100
PF24
OSCL2
Vibration tough drive function selection
Refer to Name
and function
column.
Setting
digit
Explanation
Initial
value
_ _ _ x Oscillation detection alarm selection
0: [AL. 54 Oscillation detection] will occur at oscillation detection.
1: [AL. F3.1 Oscillation detection warning] will occur at oscillation
detection.
2: Oscillation detection function disabled
Select alarm or warning when a oscillation continues at a filter
readjustment sensitivity level of [Pr. PF23].
The digit is continuously enabled regardless of the vibration tough
drive in [Pr. PA20].
0h
_ _ x _ For manufacturer setting 0h
_ x _ _ 0h
x _ _ _ 0h
PF25 CVAT Instantaneous power failure tough drive - Detection time
Set the time of the [AL. 10.1 Voltage drop in the control power] occurrence.
To disable the parameter, select "Disabled (_ 0 _ _)" of "Instantaneous power failure tough
drive selection" in [Pr. PA20].
200
[ms]
30 to
200
PF31 FRIC Machine diagnosis function - Friction judgement speed
Set a motor speed to divide a friction estimation area into high and low for the friction
estimation process of the machine diagnosis.
However, setting "0" will be the value half of the rated speed.
When your operation pattern is under rated speed, we recommend that you set half value to
the maximum speed with this.
ㆇォᤨᦨᄢㅦᐲ
[Pr.PF31]⸳ቯ୯
ㆇォࡄ࠲ࡦ
0r/min
ࠨࡏࡕ࠲
࿁ォㅦᐲ
ᱜォᣇะ
ㅒォᣇะ
0
[r/min]
0 to
Permiss
ible
speed
Servo motor
speed
Forward
rotation
direction
Reverse
rotation
direction
0 r/min
Operation pattern
Maximum speed in operation
[Pr. PF31] setting