Main code Sub code Content
30 01 Paper sensor state display
Used to monitor the ON/OFF state of the sensors in the main body with the LED on the operation panel.
Sensor name Operation panel LED
PID Manual feed tray selection lamp
PPD Drum position jam lamp ()
DPPD1 Resist position jam lamp ()
POD Paper exit position jam lamp ()
PED1 Body upper step tray selection lamp ()
42 (Note) Developer counter clear
Used to clear the currently installed developing unit counter and to display the developer counter value on the
copy quantity display.
(“000” is displayed because the counter is cleared.)
(Note) The counter is cleared by entering the sub code “01.”
43 01 Fusing temperature setting
Used to set the fusing control temperature.
When this simulation is executed, the currently set fusing temperature is displayed on the copy quantity display.
The set value is changed by pressing the magnification ratio display key.
Select the fusing temperature and press the PRINT button to store it.
The setting range is 160 205°C (in the increment ofC).
44 01 Process control operation setting
Used to set valid/invalid of the grid voltage correction, optical dirt correction, and drum membrane decrease
correction.
When this simulation is executed, the currently set value is displayed on the copy quantity display.
To make each correction mode valid, enter the sum of the codes of the correction modes, and press the PRINT
button to store it.
Code Correction mode
+1 Grid voltage correction
+2 Optical dirt correction
+4 Drum membrane decrease correction
The initial value is “7.” (All corrections are valid.)
The grid voltage correction is always valid regardless of set value. (Even if it is set to “0,” the grid voltage
correction is not canceled.)