Main code Sub code Content
26 10 AE original density setting
Used to set the original density.
When this simulation is executed, the currently set original density is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value Original density
0 Normal Initial value
1 Thin original
When a dark original is copied in the AE mode, the lead edge (about 4mm) is not copied. If it is necessary to copy
the lead edge, set this simulation to “1.”
13 Warm-up mode setting
Used to set the main motor operation mode during warm-up.
When this simulation is executed, the currently set warm-up mode is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value Warm-up mode
0 Normal mode Initial value
1 The main motor rotates until warm-up is completed.
18 Toner save mode setting (Japan/SUK only)
Used to set ON/OFF of the toner save mode.
When this simulation is executed, the currently set value is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value Toner save mode
0ON Initial value
1 OFF
20 Rear edge void setting
Used to set YES/NO of the paper rear edge void.
When this simulation is executed, the currently set rear edge void mode is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value Rear edge void
0 Yes Initial value
1No
29 AC power voltage setting
Used to set the AC power voltage to 100V or 200V.
(For compliance with the CE mark)
Set value Power voltage
0 100V series Initial value
1 200V series
8 – 8