D. Note for toner hopper drive gear (31T) and stirring
shaft attachment
• Be careful of the stirring shafts A and B attachment positions.
Attach so that the angle between stirring shaft A and B is 90
degrees.
• When attaching the toner hopper drive gear (31T), be careful of
the E-ring stop position as shown below. (If the E ring is on the
milled surface, it is apt to disengage.)
8.Operation panel/intermediate cabinet
1 Open the front cabinet.
2 Remove two screws A, two screws B, and two harnesses con-
nected to the operation panel unit.
2 Remove the operation panel unit.
3 Remove the process cover unit, remove six screws C and two
connectors, and remove the intermediate cabinet.
9. Frame major parts
9-1. Cooling fan motor replacement
A. Cooling fan motor removal
1
Remove the original cover, the original guide, the upper cabinet
left, and the upper cabinet right.
90
Stirring shaft B
Stirring shaft B
31T gear
B
A
A
C
C
6 – 21