Copy density adjustment
Item Content
Automatic exposure level initial setting 3 (Standard level)
TSM mode initial setting 5 (Standard mode)
AE sensor level adjustment Execution of Sim. 47
Drum sensitivity setting Execution of Sim. 26-07
Test chart setting Test chart comparison table
SHARP CORPORATION
MADE IN JAPAN
Copy density adjustment
Developing bias output voltage adjustment 200V (Manual exposure 1)
Execution of Sim. 8-01
Manual exposure copy density adjustment Execution of Sim. 46-01
ME1
ME5
TSM mode copy density adjustment
TS1
TS5
Photo mode copy density adjustment
PE1
PE5
1
10
W23
45
6
789
Not copied Slightly copied
1
10
W
2
345
6
78
9
Not copied Copied
1 10
W
2
34
5
6
789
Not copied Slightly copied
1
10
W
234
5678
9
Not copied Copied
1 10 W
2
3
456
7
89
Not copied Slightly copied
1 10 W2
3456
7
89
Not copied Copied
UKOG-0162FCZZ
DENSITY No.
12345678910 W
UKOG-0089CSZZ
DENSITY No.
0.1 0.2 0.3 0.5 1.9 0
KODAK GRAY
SCALE
123419A
7 – 19