6-5. Discharge lamp unit (Clean every 60K copies.)
1 Remove three blue screws which are fixing the process unit
holder, slide the holder and remove it.
2 Remove the discharge lamp unit. (one screw, one connector)
6-6. Cleaner blade (Replace every 60K copies.)
1 Remove the holder from the process unit. (3 blue screws)
2 Remove the cleaning blade. (3 blue screws)
6-7. Drum separation pawl (Replace every 60K
copies.)
Slide and remove the blue pin to remove the separation pawl.
Replace the star-shape washer with a new one if it is worn down.
6-8. Process control PWB (Clean the sensor
section every 60K copies.)
1 Remove the holder from the process unit (3 blue screws), and
remove the connector of the process control PWB.
2 Remove the holder of the process control PWB (2 screws), and
remove the PWB (2 screws).
6-9. Drum mark sensor PWB (Clean the sensor
section every 60K copies.)
Remove the holder from the process unit (3 blue screws), and
remove the marking sensor PWB. (1 screw).
6-10. Toner reception seal (Replace every 60K
copies.)
Remove the drum and remove two screws to remove the seal.