(3) User simulation code table
Program
Sim.
code
Selection code:
Set content
Factory setting
Auto clear passing time setting
[1]
[0]: Cancel
[1]: 30 sec
[2]: 60 sec
[3]: 90 sec
[4]: 120 sec
2
Pre-heat mode setting and passing time
setting
[2]
[0]: Cancel
[1]: 1 min
[2]: 15 min
[3]: 60 min
[4]: 120 min
2
Auto power shut off mode setting and passing
time setting
[3]
[1]: 5min
[2]: 15 min
[3]: 30 min
[4]: 60 min
[5]: 120 min
[6]: 240 min
3
Auto pre-heat control mode setting and cancel
[4]
[0]: Cancel
[1]: Setting
1
Auto document feeder manual document feed
mode setting
[5]
[0]: Cancel
[1]: Setting
0
Sorter take-out mode
[7]
[0]: Cancel
[1]: Setting
1
Auto power shut OFF setting
[20]
[0]: Cancel
[1]: Setting
0
(4) Department counter setting content (Set with user program P10 ∼ P15)
Function name Setting content Factory setting
P10 Department counter
setting/cancel
The department counter is set or canceled.
Cancel
P11 Department No. registration The department number is registered. Up to 20 departments can be
registered.
No setting
P12 Department No. change The registered department number is changed. No change allowed.
P13 Department No. delete The registered department numbers are deleted.
One department number or all the department numbers can be deleted.
No delete allowed.
P14 Copy quantity display (Total) The copy quantity of each department is displayed.
The count is made up to 50,000. After that, the count starts from 0 again.
No display allowed.
P15 Copy quantity delete (Total delete) The counted copy quantity is deleted.
One department or all the department can be deleted.
No display allowed. (*)
(*): Because of no registration of department No. at all.
8 – 17