ER-OIPU
i No. I COMMAND I
FUNCTION
I
CODE
I
Select/cancel
47
ESC z n receiptijoumal same
<1Bh><7Ah> n
data printing
L
[Range]
OS n S 255
[Function]
Select or cancel printing the same data on the receip~ournal. When
the value of bit Oof “n” is equal to O,same data printing is canceled.
When the value of bit O of “n” is equal to 1, same data printing is
selected.
When same data printing is selected, the amount of data to be sent
from the host computer may be for one print sheet only (360 dots).
[Notes]
Valid only at the beginning of a line.
[
No.
I COMMAND
FUNCTION CODE
1
I
48 ESC { n
Set/cancel upside-down
i
Cl Bh><7Bh> n
character Drintina
I
[Range]
OS n S 255
[Function]
Sets or cancels upside-down character printing.
Only the lowest bit of “n” is valid.
When bit O is equal to O, upside-down character printing is can-
celed.
When bit Ois equal to 1, upside-down character printing is set.
[Notes]
Valid only when entered at the beginning of a line.
[Default]
n=O
No.
COMMAND FUNCTION
CODE
49
Gs ! n
Select character size
<1Dh>e21h> n
[Range]
OS n S 255
[Function]
Selects the character size of Normal/Double/Quadruple
Width).
bit
Function
o Height
000: Normal
1
001 : Double
2
011 : Quadruple
3
4 Width 000: Normal
5
001 : Double
6
011 : Quadruple
7
[Notes]
Height represents the vertical direction; width represents
tal direction.
(Height and
the horizon-
When 90” cw rotated character printing is set, height and width are
reversed.
Double-heightidouble-width selected using ESC ! is disabled by this
command.
[Default]
n=O
[Reference]
IESCI !: Set character mode
\ No. \
COMMAND
I FUNCTION I
CODE I
I
50 GS *nl n2 [data] k
Set image data I c1Dh><2Ah> ...
[Range]
1~ nl ~
45:
Horizontal size
1 ~ n2 s 255: VertiCalSiZe
nl x n2 S 1800
0 S data S 255
[Function]
●
●
Defines the image data with the number of dots specified by nl
and n2.
me number of dots in the horizontal direction is nlx8, and in the
vertical direction is n2 x 8.
“data” specifies the bit image data.
Black printing is 1; white printing is O.
[Notes]
● The set user-defined character data is not cleared until the
MASTER RESET and ESC Q commands are received.
● If the above-mentioned data is out of the range, the setting is
disabled.
4-15