No.
COMMAND
FUNCTION
CODE
34
ESC c On
Select print sheet (R/J)
<1Bh><63h><30h> n
[Range]
o~n~z
[Function]
Enables or disables the print sheet (FVJ).
The meaning of each bit of “n” is as follows.
bit
Description
0/1
o Journal printer
Disabled/Enabled
1 Receipt printer Disabled/Enabled
2
3
41
I
5
6
71
I
[Notes]
Valid only at the beginning of a line
[Default]
n=3
No.
COMMAND
FUNCTION
CODE
Select print sheet
35
ESC c 1 n covered by line teed
<1Bh><63h><31h> n
amount settina
[Range]
OSn S3
[Function]
Enables or disables the data of line feed amount setting
(ESC2/ESC3) by print sheet (receipt/journal).
The meaning of each bit of “n” is as follows.
bit Description
0/1
o
Journal printer
DisabledfEnabled
1 Receipt printer Disabled/Enabled
2
3
4
5
6
7
[Notes]
Valid only at the beginning of a line
[Default]
n=3
ER-OIPU
No. COMMAND
FUNCTION
CODE
Select paper-end
36 ESC c 4 n
detector to stop
<1Bh>c63h>c34h> n
printing
*
[Range]
OS n S 255
[Function]
Selects which paper-end detector causes the printer to stop printing.
When printing is stopped, the line being printed is completed.
Even if printing stop is invalid, the printer stops printing and the print
data is discarded when the paper is out.
The meaning of each bit of “n” is as follows.
bit
Description
0/1
o
Near-end detector
InvaliWalid
1
2
Journal end detector
Invalitialid
3
Receipt end detector
Invalid/Valid
4
5
6
7
[Notes]
Whether the printer goes OFF-LINE or not depends on the setting of
the dip switch.
Caution
When the presetting of Receipt is different form Journal
and if the line spacing is less than 6 dota,
printing may be disturbed when printing is started
from the nrinter stoo state.
[Default]
n=O
I
37
I
ESC c 5 n
Enable/disable
Danelswitch
I
cl Bh>e63h>c35h> n
I
[Function]
Enables or disables the panel switch.
Only the lowest bit of “n” is valid.
When n=*******
O,the panel switch is enabled.
When n=*******
1, the panel switch is disabled.
[Notes]
This command is valid for the receipt feed key, journal feed key and
online key,
[Default]
n=O