Building component
General term for any individual part of the building envelope. Usually applied
to doors, windows and walls.
Building envelope
The total of the boundary surfaces of a building, through which heat (or air) is
transferred between the internal spaces and the outside environment.
Calibration
Operation where the output of a measuring device is compared with reference
standards, to accurately quantify the results provided by the measuring device.
Capacitance pressure transducer
A device with a metal diaphragm sensing elem ent acting as one plate of a capa-
citor. When pressure is applied it moves with respect to a fixed plate, changing
the thickness of the dielectric between. The resulting signal is monitored using
a bridge circ uit.
Cell
Volume in a room limited by a theoretical or physical surface, in which the
physical quantities of interest can be considered as homogeneous. A room
can be divided in several cells.
Chemical indicator tubes (or Dra
¨
ger
1
tubes)
Glass tubes containing an adsorbing material that changes colour in the
presence of a specific gas.
Compensated flowmeter
Airflow rate measuring instrument in which a fan compensates the pressure
drop required by the measuring device.
Component leakage
The leakage of air through the building envelope or internal partitions, which is
directly attributable to flow through cracks around doors, windows and other
components.
Concentration
Ratio expressing the amount of a chemical comp onent in a mixture. This ratio
may be expressed in terms of mass, of volume or of number of molecules. In air,
it can also be the ratio of the mass of component divided by the volume of air.
Condition number
Number expressing how much the errors in measured data are enlarged when
transmitted, through the interpreting equations, to the final results.
Conductance
Generally, any path allowed for air between two zones. Also the ratio of the flow
rate through a path to the pressure differential across that path.
Connected space
A space in a building adjacent to the measurement space with which significant
exchange of air may take place, thus increasing the effective volume of the space.