5.6 Calibrate angle scale
To calibrate the angle scale, a copy-grinding plate
is inserted in the machine with the relevant knife.
Set the selection switch "Manual / Automatic" to
Automatic and press the "Start" button. Check the
distance between the abrasive belt and the copy
plate. For a grinding angle of 25°, the distance
must be 6 mm.
After pre-adjusting to approx. 6 mm, set the selec-
tion switch to "Manual" and fit a new abrasive belt
on the machine USK 230. On the control panel,
set the number of cycles for the 0 feed to 10 and
the number of feeds to 0. Set switch "Manual /
Automatic" to Automatic and press "Start" button.
Now a bevel is cut on the knife. At the end of the
program, unclamp the knife and measure the
angle cut with the angle gauge provided.
Set the measured angle on the angle scale. For
this, release the clamping lever (5-3/1) and push
the angle scale up until the measured angle is set
(see Fig. 3-8). Tighten clamping lever (5-3/1).
Then set the required angle with the handwheel of
the grinding angle adjustment. Sharpen the knife
again and check the angle. Readjust the scale if
necessary.