6. R232C INTERFACE
6-1. General specification
Input/output format
RS-232C bit serial inpul/output
No of channels
1 channel
Code used
JIS 7-channe(/JlS 8 channel
Baud rate
110 to 9600 bits/sec
Transmission system
Half-duplex
Synchronization method
Start-stop
Communication control
procedure
Non-procedure
Data format
Stop bif 1/1.5/2, with or without
even or odd parity.
LSI used
8251 AC or 8253C-5
(Programmable Interval Timer)
6-2. Data transmission format
gO g' 2^ 2^ 2^
7-bit,
with parity
Start bs\
Data bit (7 bits) Parity bit Stop bit (1 or 2 bits)
7-bit,
without parity
Start bit
------
Y
-------
Data bit (7 bits)
Stop bit
8*bit,
with parity
Start bit
Data bit (8 bits) Parity bit Stop bit <1 or 2 bits)
8-bit,
without parity
Start bit
Data bit 18 bits)
Stop bit (1 or 2 bits)
Example: 7-bits, even parity, 1 stop bit
2° 2' 2^ 2® 2'* 2® 2®
Start bit
Stop bit of preceding data
7-bit data {26H}
Panty bit
Stop bit
Start bit of
succeeding data
71