AR-168S/168D TEST COMMAND, TROUBLE CODES 10 - 14
26 30 CE mark support control ON/
OFF (CE MARK)
[Function]
When this test command is executed, the current set CE mark support control is displayed. Enter the
code number corresponding to the desired CE mark support control and press [ENTER/START] key
to save the setting.
[Operation]
The operation is similar to test command 21-01.
37 Cancel of stop at developer
life over (DVLP LIFE END)
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
39 Memory capacity check
(MEM.CHK)
[Function]
When the test command is executed, the currently installed SDRAM of the main unit is displayed.
[Operation]
40 Polygon motor OFF time
setting (Time required from
completion of printing to
turning OFF the motor) (LSU
MOTOR OFF)
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
42 Transfer ON timing control
setting (TC ON TIMING)
[Function]
When this test command is executed, the currently set value of the transfer ON timing is displayed
(initial display), and the set value is saved. (Setting range: 0 9, Default: 5)
The default 5 of transfer ON timing is 330ms passed from PS release.
When set to 0, it is the same as setting to 5.
[Operation]
The operation is similar to test command 21-01.
Main
code
Sub
code
Contents Details of function/operation
Code number Setting Display item Remark
0 CE mark support control OFF OFF Default (100V series)
1 CE mark support control ON ON
Code number Setting Display item Remark
0 Stop at developer life over STOP
1 Cancel of stop at developer life over NONSTOP
Code number Setting Remark
88 MBYTE
1) Memory capacity display
26-39 MEM.CHK
8 MBYTE
Code number Setting Display item Remark
00sec0 SEC.
1 30sec 30 SEC. Default
2 60sec 60 SEC.
3 90sec 90 SEC.
Code Setting Remark
00 msec
1 40 msec
2 30 msec
3 20 msec
4 10 msec
5 0 msec Default
6 +10 msec
7 +20 msec
8 +30 msec
9 +40 msec