Sharp DT-200L Manual de Instruções Página 46

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 53
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 45
44
8.7 Adjustment of Laser Beam
This adjustment must be done after completing following checking and
adjusting. 8.3 “Adjustment of the Vertical Cross-hair”, 8.4 “Collimation of the
Instrument”.
In intersection of the cross-hair does not coincide with the laser spot, turn the
laser axis adjusting screws to move the laser spot to coincide with intersec-
tion of the cross-hair.
1
Remove the caps of the laser axis adjusting screws with coin.
As shown below, the screws are called A and B.
2
Following shows the moving direction of the laser spot by turning the
laser adjusting screws.
3
Attach the caps of the laser axis adjusting screws.
WARNING
Aiming the instrument into prism or highly reflective surface can re-
sult in serious damage to your eye because the optical axis and la-
ser beam source is in coincidence.
Do not aim the instrument directly into prism or highly reflective sur-
face.
Do not look at the laser beam directly.
Laser axis adjusting screw B
Laser axis adjusting screw A
Turn screw A
counterclockwise
Turn screw B
counterclockwise
Laser spot
Laser spot
Turn screw A
clockwise
Turn screw
B
clockwise
Vista de página 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 52 53

Comentários a estes Manuais

Sem comentários