Sharp DT-200L Manual de Instruções Página 24

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 53
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 23
22
3.3 Measuring from the Required Horizontal Angle
1
Display the required horizontal angle using the horizontal motion
clamp and horizontal tangent screw.
2
Press the [HOLD] key.
The display of horizontal angle blinks and the horizontal angle will
be held.
To return to the angle status before the data is held, press any key
except the [HOLD] key.
3
Collimate the target to set.
4
Press the [HOLD] key. The angle measurement will start from the
held angle.
3.4 Vertical Angle % display
1
Press the [V/%] key.
Every time pressing the [V/%] key, the mode switches.
When the measurement is carried out over than 4 from the
horizontal, the display shows [ --------].
V 90°10’20”
HR 130°40’20”
V 90°10’20”
HR 130°40’20”
blinks
V 90°10’20”
HR 130°40’20”
V 66°23’10”
HR 120°30’40”
V 43.719%
HR 120°30’40”
Vista de página 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 52 53

Comentários a estes Manuais

Sem comentários