Function switches
Position
of
function switches
When the
ROM
unit holder cover
is
removed from this
machine, two multiple-switches are found on the lower
side
of
the
ROM
unit. These are called "function switches".
Before operating the printer, set these function switches
following the procedure described below.
Setting the function switches
SW2
SW1
~~~~~~~~~~
IEx.1
J lEx.!
SW2-8
J
SWI-2
Fig.
23 Switch Nos.
of
function sw.ltehes
By setting the function switches, the state
of
the printer after turning
on
power can be determined.
Follow the procedure described below, in operating the function switches.
I.
Confinn that power
is
turned
off
while the
ROM
unit is connected
to
MZ-80P4.
2.
Next, set the function switches representing the desired operations.
3.
Turn on power for MZ-80P4.
(Caution)
Do not operate the function switches while power
is
turned on. Otherwise, wrong operation
or
trouble may be caused.
Functions
of
function switch SWl
The switch
SW
I has common functions for any
ROM
unit.
SWl-l
Designates the size
of
66 lines/page
72 lines/page
one page
(See Note
1)
--
----
. -
SW\-2
Designa tes the distance
Distance: 1/6 in. Distance:
1/3 in.
between lines (See Note 2)
--
SWl-3
Selects 0 print indication
"Q"indication
"0" indicatior
SWI-4
Processes ON-LINE/ ON-LINE OFF-LINE
OFF-LINE after power
("Select" condition
(The green light goes
is
turned on emerges, and the green OFF.)
light goes
ON.)
_.
SW\-S
Selects printing system
136 characters/line
160 characters/line
i
mode (Pica pitch) mode
SW\-6
Memory backup
Memory backup
Memory backup
is
function function
is
actuated
no! carried out.
by
cell. (Note 4)
The position selected
when power
is
turned
I
on
is
regarded
as
form position.
(Note
l)
Setting can be changed by the use
of
software.
(Note 2) Priority
is
given to the designation by the switch
in
regard to changing lines.
For
example,
compression by control code will be 2/9 inch when the distance between lines is set at 1/3
inch.
(Note 3) In the I 36-character mode, the space
dot
between characters
is
expanded to 2 dots.
(Note 4)
If
there
is
not
electricity in the cell when this switch
is
turned ON, the position selected
when power
is
turned on
will
not
become fonn position.
11