3.40
Operating
Procedures
3.4.1
Frequency
and
Deviation
'Ieasuremenl
It
is
assumed
that
the
CE-7
is
equipped
with
a Model 303
Broadband
Xlixer
and
either
the
Model 301
Oscilloscope
or
the
Model 302
FM
Deviation
Meter
.
For
measurement
of
frequency
and
deviation
with
one
of
the
RF
Preselectors
in
-stead
of
the
Model 303,
the
same
procedure
is
followed
except
that
the
preselector
frequency
dial
must
be
set
to
the
frequency
selected
with
the
CARRIER
'FREQUENCY
SELECTOR.
a.
Connect
the
telescoping
antenna,
an
external
antenna,
0 r
other
signal
source
to
the
ANT.
connector
on
the
Broadband
Mixer
or
Preselector.
If
the
telescoping
antenna
is
used,
ex-
tend
it
to
its
full
length
for
meas-
urements
of
signals
below
30 MHz
to
approximately
18
inches
for
VHF
measurements;
use
minimum
length
for
UHF
measurements.
b.
Select
the
desired
carrier
frequency
with
the
CARRIER
FREQUENCY
SELECTOR.
c.
Place
the
function
switch
in
the
HARM.
AMP.
TUNIKGpositionand
adjust
the
HARM.
AMP.
TUNIKGcontrolforamaxi-
mum
reading
on
the
FREQCENCY
meter.
The
HARM.
A:'IP.
TCNING
control
should
indicate
the
appropriate
number
recorded
on
the
Channel
Frequency
Chart.
d.
Turn
the
function
switch
to
CAL.
/
C\\'.
The
SIG::\AL
LEVEL
lamp
should
light.
e.
Adjust
the
inner
red
knob
(concen-
tric
with
the
function
switch)
for
a
zero
(mid-scale)
reading
on
the
FREQUENCY
meter.
f. If
the
Model 301
Oscilloscope
is
being
used,
set
the
toggle
switches
for
horizontal
and
vertical
inputs
to
the
INT.
positions
and
adjust
the
VERT.
POS.
control
so
that
the
trace
is
on
the
zero
reference
line
while
the
deviation
range
switch
is
in
the
±l.;)
position.
Adjust
the
scope
INTEKSITY,
FOCUS, and
ASTIGrvIATIS:'I
controls
for
a
sharp
trace
on
the
screen.
3-5
5601"0015"1
g.
Set
the
function
switch
to
the
FREQ.-
DEV.
MEASURE
position.
[:~~~!~~~]
The
signal
level
applied
to
the
ANT.
connector
should
not
ex-
ceed
5
milliwatts
or
the
plug-in
may
be
damaged.
h. Key
the
transmitter
or
other
signal
source
to be
monitored.
The
SIG-
NAL
LEVEL
lamp
should
come
on.
If
it
does
not,
increase
the
signal
level
at
the
ANT.
connector.
Nor-
mally,
if
the
telescoping
antenna
is
used,
measurements
can
be
made
easily
when
the
CE-7
is
between
25
to
50
feet
from
the
radiating
antenna.
When
a
plug-in
prese-
lector
is
being
used,
measurements
can
be
made
at
distances
up
to
50
miles
from
the
transmitter
if
an
adequate
external
antenna
is
used.
i ,
The
difference
between
the
measured
signal
frequency
and
the
CE-7
carrier
frequency
is
indicated
on
the
FRE-
QUENCY
meter
according
to
the
posi-
tion
of
the
±kHz
(FREQUENCY
lever).
j.
Modulate
the
transmitter
or
other
signal
source
to
be
monitored
when
FM
deviation
is
to
be
measured.
Select
the
appropriate
full-scale
sensitivity
with
the
range
switch
(kHz)
on
the
deviation
plug-in
being
used.
When
the
oscilloscope
is
used,
positive
modulation
peaks
appear
above
and
negative
peaks
below
the
zero
reference
line;
the
FM
deviation
meter
will
indi-
cate
either
positive
or
negative
peaks
depending
on
the
setting
of
the
FM
DEV.
PEAKS
switch.
If
the
DEVIA
TION
PEAKS
indicator
on
the
FM
Deviation
Meter
has
been
calibrated
(see
Model
302
FM
Deviation
Meter
equipment
manual)
all
modulation
peaks
which
exceed
a
preset
level
will
cause
this
indi-
cator
to
light.
The
accuracy
of
deviation
measurement
may
be
affected
by
the
position
of
the
SELECTIVITY
switch
on
the
Broadband
Mixer
or
Preselector.
(Refer
to
the
applicable
plug-in
operating
instructions.
)