Sharp R-880S Manual do Operador Página 84

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 111
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 83
Specifications
82
Suction Pressure Regulator Valve Setting:
T-680R
T-880R
T-1080R
28 to 31 psig (193 to 214 kPa)
35 to 37 psig (241 to 255 kPa)
21 to 23 psig (145 to 159 kPa)
High Pressure Cutout Switch: Open
Close
470 ± 7 psig (3241 ± 48 kPa)
375 ± 38 psig (2586 ± 262 kPa)
* When the compressor is removed from the unit, oil level should be noted or the oil removed from the
compressor should be measured. This is to be sure that the same amount of oil can be added before placing the
replacement compressor in the unit.
Scroll Compressor
Unit Model: T-680S and T-880S
T-1080S
Compressor Model:
TK04 Scroll 4 HP
TK06 Scroll 6 HP
Refrigerant Charge:
T-680S and T-880S
T-1080S
7.0 lb (3.2 kg) R-404A
7.5 lb (3.4 kg) R-404A
*Compressor Oil Charge 2.0 quarts (1.9 liters)
Refrigeration System
Vista de página 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 110 111

Comentários a estes Manuais

Sem comentários