6 - 3
[2] Connecting to a power supply
Connecting a commercially available constant-voltage power supply to the power terminal (POWER:
+24V, 0 V) on the IV-08MP. Use a 24V DC±10%, 800mA or more constant-voltage power supply.
• Use an individual power supply to supply power to the IV-08MP.
• Check the polarity of the power supply terminals, +24 V and 0 V. If power is supplied with the
polarity inverted, the failure of the IV-08MP may occur.
Fuse
(1A)
Frame ground terminal
This distance must be as
short as possible.
(Recommended distance: less than 1 m)
( - )
24V DC
( + )
Constant-voltage power supply
FG 0V 24V