Sharp CV-P10LJ Especificações

Consulte online ou descarregue Especificações para Aparelhos de ar condicionado "split system" Sharp CV-P10LJ. Sharp CV-P10LJ Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - CV-P13LJ

PORTABLE TYPEROOM AIR CONDITIONERINSTALLATION AND OPERATION MANUAL HSILGNELOÑAPSE CV-P10LJ CV-P13LJ

Página 2 - CONTENTS

INSTALL WINDOW PANELInstallation in a sliding sash window HoleProjectionInsect guard netRain guard"A"Window panelProjection"A"Wi

Página 3 - NOTES ON OPERATION

If the inner height of the window is between 24" (609mm) and 36.8" (934mm) inclusive. (1) Open the window sash and place the window panel o

Página 4 - LOCATION

Exhaust hoseWindow ex-haust adapterProjectionExtendHole"TOP"E-11The exhaust hose must be installed or removed in accordance with the usage m

Página 5 - INCLUDED

"PUSH"ProjectionE-12Removal of the exhaust hose1 Remove the window exhaust adapter. Pull out and remove the window exhaust adapter by pushi

Página 6 - PART NAMES

E-13NOTES:• The battery should last approximately one year under normal use.• When replacing the batteries, always change both batteries at the same t

Página 7 - REMOTE CONTROL DISPLAY

ENGLISHE-14CAUTION• Do not expose the signal receiver window to direct sunlight. This may adversely affect its operation. If necessary, close the c

Página 8

E-15COOL MODEEnsure that the stopcock is securely attached the drainpipe.1 Press the MODE button to select COOL mode. COOL DEHUM FAN VENT2 Press the P

Página 9

E-16FAN MODEVENTILATION MODE213213In this mode, the air conditioner simply circulates the air without cooling it.In this mode, the air conditioner ven

Página 10 - INSTALL WINDOW PANEL

TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION NOTE• During VENTILATION mode, UP/DOWN air fl ow direction cannot be changed.Hold the vertic

Página 11

ENGLISHE-181 Press the PLASMACLUSTER button during operation.• The remote control will display “ ”.• The blue PLASMACLUSTER lamp on the unit will

Página 12 - Acceptable

ENGLISHThis manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product. This manual should

Página 13 - Removal of the exhaust hose

1 Press the MEGA COOL button during cooling mode.• The remote control will display " " .• The temperature display will go off.• The

Página 14 - PRE-OPERATION CHECKS

ENGLISH0.5h 1.0h 1.5h 10h 11h 12hON TIMER1 Press the ON TIMER button.• The time setting will change as you press the button as follows. Hold the butto

Página 15 - Remote control hook

Prepare for drainage and drain out water within the unit in the following cases.• When the unit stops operating and the TIMER, OPERATION and MEGA COOL

Página 16 - COOL MODE

ENGLISHE-22CLEANING THE UNIT AND THE REMOTE CONTROLWipe them with a soft, dry cloth or with a cloth moistened with a mild soap. Carefully remove any r

Página 17 - VENTILATION MODE

BEFORE CALLING FOR SERVICEIf the unit appears to be malfunctioning, check the following points before calling for a service.AIR CONDITIONER DOES NOT O

Página 18 - TO CHANGE AIR FLOW DIRECTION

Technical Specifications Sr No Parameter Unit Value 1 Model CV-P10LJ Rated Voltage V~ 220-240 Rated Frequency Hz 50 2 Power Supply Phases 1

Página 19 - PLASMACLUSTER OPERATION

28 Refrigerant R410A 29 Refrigerant Charge kg 0.67 30 Compressor LANDA COMPRESSOR 31 Compressor Model QXA-B102T130 32 Compressor Oil

Página 20 - MEGA COOL OPERATION

Technical Specifications Sr No Parameter Unit Value 1 Model CV-P13LJ Rated Voltage V~ 220-240 Rated Frequency Hz 50 2 Power Supply Phases 1

Página 21 - TIMER OPERATION

28 Refrigerant R410A 29 Refrigerant Charge kg 0.95 30 Compressor MITSUBISHI 31 Compressor Model RN125VHFMC 32 Compressor Oil PVE(FV5

Página 22 - DRAINAGE

Congratulations on Your Purchase!This Sharp product is warranted against faults in materials and manufacture for a periodof twelve (12) months from th

Página 23 - MAINTENANCE

ENGLISHE-2USAGE CAUTIONS• Ventilate the room periodically during use, especially if using gas appliances.• Be sure to turn the unit off and disconne

Página 24 - BEFORE CALLING FOR SERVICE

FOR LOCATION ENQUIRIES WITHINNEW ZEALANDREGARDING YOUR LOCALSHARP CORPORATION OF NEW ZEALAND LIMITEDVISIT OUR WEBSITE ATSHARP CUSTOMER SERVICESTELEPHO

Página 26

SHARP CORPORATION OF AUSTRALIA PTY LTD ABN 40 003 039 405 1 Huntingwood Drive HUNTINGWOOD NSW 2148

Página 27

MIN.12"(30cm)MIN.12"(30cm)PRECAUTIONSE-3OPERATING CONDITIONS• The air conditioner must be operated within the temperature range indicated b

Página 28

Exhaust hose 1Rain guard2Window exhaust Extension paneladapter1Insect guard net111 Foam seal A1Exhaust hose adapter 1Foam seal B(adhesive type)1Brack

Página 29 - WARRANTY

PART NAMES1Air Outlet2 Vertical louvers3 Horizontal louvers4 POWER Button5 Remote control signal receiver window6 OPERATION Lamp (red)7 TIMER Lamp (o

Página 30 - 1300 135 022

ENGLISHREMOTE CONTROL1 Transmitter2 Display 3 POWER Button4 LIGHTS Button5 TEMPERATURE Button6 PLASMACLUSTER Button7 SLEEP Button8 MODE Button9 ON TIM

Página 31

INSTALL WINDOW PANELHoleProjectionInsect guard netRain guard"A"Window panelProjection"A"Window panelE-7Foam seal A(adhesive type)I

Página 32 - 66129905937

Foam seal A(adhesive type)Adjustment panelExtension panelE-8If the inner width of the window is between 24" (609mm) and 36.8" (934mm) inclus

Comentários a estes Manuais