Section-3 Operation
October 17, 2013
338
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 8882693004
3.7.5.3 RTACProfilessubwindow
ProfileLinear:ForlinearRTACcorrection,BASICand LONGOFFSETprofilesshouldbetriedfirst.Theruleofthumb
hereisthatmoreisnotnecessarilybetter,sousethefirstprofilethatworkswell.Theequalizerlengthintime
generallyincreasesdownthelist.Linearprofilechoicesare:
BASICThiscorrectionshouldbeusedformoststandardmaskfilters.
SHORT
LONG
MAX
BASICOFFSET
SHORTOFFSET
LONGOFFSETThiscorrectionshouldbeusedforsharptunedmaskfilters,specialmask
filters,orwhenatwoormoretransmittersofdifferentfrequenciesarebeingcombin ed
intoasingleoutputthrough2ormoresharptunedfilters.
MAXOFFSET
ProfileN
onlinear:Fornonlin earRTACcorrection,thenamedprofilesshouldbetriedbeforethenumberedprofiles.
MosttransmittersshoulduseBASICorBASICMEMORY.However,iftheydonotgivesatisfactoryadjacentchannel
intermodulationperformance,ahigherprofilesuchasHIGHorHIGHMEMORYshouldbeused.Nonlinearprofi le
ch
oicesare:
BASIC
BASICMEMORY
PROFILE3
PROFILE4
HIGH
HIGHMEMORY
PROFILE7
PROFILE8
PROFILE9
3.7.6 DUC/RTACSetupScreen5
Figure 3-36 LPU RTAC Screen 5
Upconverterc
orrectionmaybeusedtocorrectanynonlinearfrequencyresponseinthemodulatorRFupconverter.
Thisoperatessim ilarlytoLinearRTAC.Refertoinstructionsinwindow.