3.9 Programming the HOME position in
LPKF
BoardMaster
The H
OME
position for the LPKF ProtoMat 95s/II must be programmed to lie exactly on the
axis of symmetry (the registration hole system with the red plastic slides) as described for
machining double-sided boards. You must enter a correction if a check shows that the H
OME
position, as described above, does not lie on the axis of symmetry.
To do this, proceed as follows:
1.
Start up BoardMaster.
2.
Select
C
ONFIGURATION
, S
ETTINGS
from the menu bar.
3.
Click on
U
NLOCK
so that you can make entries in this dialogue box.
4.
If necessary, correct the H
OME
position coordinates by increased or decreasing the
value by the value previously measured.
5.
The new values will only be saved once the
M
ACHINE
S
ETTINGS
...
dialogue box is
closed and you quit BoardMaster.