General Information and Specification
Operating Limits - Models 322, 323
AC Mode: 132 VAC Max., 108 VAC Min.
DC Mode*: 15.4 VDC Max., 11.5 VDC Min.
Gas Mode: 11" W.C. Gas Supply ± 0.5" W.C.
10.5" W.C. Min. Burner Pressure
(High Fire)
Models 322, 323 Ratings
LP Gas Mode: 640 BTU/Hr Input
11" W.C. Gas Supply
.010" Orifice (LP10)
AC Mode: 110 Volts AC, 140 Watts
DC Mode*: 12 Volts DC, 140 Watts
Current Draws - 322, 323
AC Heating Element - 1.3 amps @ 110 Volts AC
1.4 amps @ 120 Volts AC
DC Heating Element* - 11.7 amps @ 12 Volts DC
13.6 amps @ 14 Volts DC
* 3-Way Models Only (Model 323)
General Instructions - Models 322, 323
The refrigerator described herein is designed and
certified for built-in installations.
Model 323 is shipped from the factory as a 3-Way
model to operate on propane gas, 120 volts AC or
12 volts DC.
Model 322 is shipped from the factory as a 2-
Way unit to operate on propane gas or 120 volts
AC electric.
To confirm that the installation is adequate, check for:
a. Adequate ventilation (See Section 2 on "Ventila-
tion Requirements").
b. Both gas and electrical components installed
and operating in a safe condition.
c. Adequate seal between refrigerator mounting
flange and cut-out opening.
d. Installed on a solid floor (not on carpet) and se-
c
u
r
e
d
by screws through holes provided.
THIS REFRIGERATOR IS NOT INTENDED TO BE
OPERATED AS A FREE STANDING UNIT (I.E.
WHERE THE PRODUCTS OF COMBUSTION ARE
NOT COMPLETELY SEALED OFF FROM THE LIV-
ING AREA) OR INSTALLED IN SUCH A WAY AS
TO CONFLICT WITH THESE INSTALLATION IN-
STRUCTIONS. UNAPPROVED INSTALLATIONS
COULD RESULT IN SAFETY RISKS OR PER-
FORMANCE PROBLEMS.
Fuse Replacement Data
(Refrigerator Control Panel)
AC Circuit: 3 amp Type 3AG (1 1/4" x 1/4")
Norcold Part No.: 61654622
DC Circuit: 20 amp Type 3AG (1 1/4" x 1/4")
Norcold Part No.: 61440522
Gas Circuit: None
WARNING
2