LC-20S4U-S
18
Page No. Item
Initial
Function
Response precautions on servicing
Value (Do not change other items than designated.)
1 MODEL A627B
MODEL NUMBER SELECT NOT MODIFIABLE
INCH SIZE 20
SCREEN SIZE SELECT
USED FOR ADJUSTMENT PROCESS
(20-INCH AND 13/15-INCH SETTINGS
INITIALIZATION, NOT MODIFIABLE FOR
NOT SWITCHABLE IN CASE OF
OTHER CASES. DATA REWRITE AND
DIFFERENT SYSTEMS)
READJUSTMENT REQUIRED WHEN INITIALIZED.
ERROR NO RESET 0
LAMP ERROR COUNT AND RESET SEE THE LAMP ERROR DETECTION.
PUBLIC MODE OFF
HOTEL MODE SETTING NOT USED
V-CHIP 1
VCHIP LINE MUTE SETTING NOT USED
EXT CONTROL ON
BUS, UART OPEN NOT USED
ROM AND GAIBU VERSION NUMBERS DISPLAYED AT THE BOTTOM.
VIDEO ADJUSTMENT
2 COM BIAS 120
COMMON BIAS ADJUSTMENT SEE THE ADJUSTMENT PROCEDURES.
TAMP L 155
Y LOWER LIMIT SETTING AT TAMP ADJUSTMENT
NOT USED
YDATA —
DATA READ VALUE AT TAMP ADJUSTMENT
SEE THE ADJUSTMENT PROCEDURES.
TAMP H 158
Y UPPER LIMIT SETTING AT TAMP ADJUSTMENT
NOT USED
NTSC TAMP 120 TAMP ADJUSTMENT SEE THE ADJUSTMENT PROCEDURES.
PAL-M TAMP 96 TAMP ADJUSTMENT SEE THE ADJUSTMENT PROCEDURES.
PAL-N TAMP 96 TAMP ADJUSTMENT SEE THE ADJUSTMENT PROCEDURES.
BACKGROUND ADJUSTMENT
3
R CUTOFF2 0 RED CUT-OFF ADJUSTMENT 2 SEE THE ADJUSTMENT PROCEDURES.
G CUTOFF2 0 GREEN CUT-OFF ADJUSTMENT 2 SEE THE ADJUSTMENT PROCEDURES.
B CUTOFF2 0 BLUE CUT-OFF ADJUSTMENT 2 SEE THE ADJUSTMENT PROCEDURES.
R-GAIN 0 WHITE BALANCE ADJUSTMENT 2 SEE THE ADJUSTMENT PROCEDURES.
G-GAIN 0 WHITE BALANCE ADJUSTMENT 2 SEE THE ADJUSTMENT PROCEDURES.
B-GAIN 0 WHITE BALANCE ADJUSTMENT 2 SEE THE ADJUSTMENT PROCEDURES.
RGB GAMMA 1.0 RGB γ COEFFICIENT SETTING NOT USED
TABLE OF VARIOUS SETTINGS
9I
2
C DATA 0
I
2
C BUS CONTROL IC DATA WRITE AND READ
NOT USED
I
2
C DATA
WAIT WRITE AND READ EXECUTED NOT USED
SOUND —
SHIFT TO THE SOUND ADJUSTMENT PAGE
USE ENTER KEY TO GO TO THE SOUND ADJUSTMENT PAGE.
DVP —
SHIFT TO THE DVP ADJUSTMENT PAGE
USE ENTER KEY TO GO TO THE TC ADJUSTMENT PAGE.
TUNER —
SHIFT TO THE TUNER ADJUSTMENT PAGE
USE ENTER KEY TO GO TO THE TUNER ADJUSTMENT PAGE.
OTHERS —
SHIFT TO THE OTHER ADJUSTMENT PAGE
USE ENTER KEY TO GO TO THE OTHER ADJUSTMENT PAGE.
BASIC SETTINGS
Page No. Item
Initial
Function
Response precautions on servicing
Value (Do not change other items than designated.)
AUDIO ADJUSTMENT PROCESS SPECIFICATIONS
AUDIO ADJUSTMENT
SOUND1 VOLUME 20 SOUND VOLUME
NOT USED
MSP DATA 0
AUDIO IC MSP DATA WRITE AND READ
NOT USED
MSP DATA
WAIT
WRITE AND READ EXECUTED
NOT USED
CARRIER MUTE ON
AUDIO OUTPUT SETTING WITHOUT TV SYNC
NOT USED
IGR THR 12D IGR THRESH LEVEL
NOT USED
AUDIO ADJUSTMENT
SOUND2 PRESCALE SCART 27
PRE-SCALE SETTING (EXTERNAL INPUT)
NOT USED
PRESCALE FM/AM-M 31 PRE-SCALE SETTING (TV) NOT USED
LIST OF THE ADJUSTMENT PROCESS MODE MENU
For calling the adjustment process mode and keying in this mode, refer back to "ADJUSTING PROCEDURE OF
EACH SECTION".
ADJUSTMENT PROCESS 1st LEVEL ITEM DEFAULT TABLE