R-419CK
In the interest of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con-
tain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe,
possibly fatal, electrical shock. (High Voltage Capacitor, High
Voltage Power Transformer, Magnetron, High Voltage Recti-
fier Assembly, High Voltage Harness etc..)
TABLE OF CONTENTS
Page
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO
AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY....................INSIDE FRONT COVER
BEFORE SERVICING ......................................................................................................INSIDE FRONT COVER
WARNING TO SERVICE PERSONNEL............................................................................................................... 1
MICROWAVE MEASUREMENT PROCEDURE................................................................................................... 2
FOREWORD AND WARNING ............................................................................................................................. 3
PRODUCT SPECIFICATIONS ............................................................................................................................. 4
GENERAL INFORMATION ................................................................................................................................. 5
OPERATION ........................................................................................................................................................ 6
TEST PROCEDURE ............................................................................................................................................ 8
PICTORIAL DIAGRAM ....................................................................................................................................... 11
LSI UNIT CIRCUIT ............................................................................................................................................. 12
PARTS LIST ....................................................................................................................................................... 13
PACKING AND ACCESSORIES ........................................................................................................................ 17
S100M140R419E
R-419CK
MICROWAVE OVEN
MODEL
SUPPLEMENTAL SERVICE MANUAL
SHARP ELECTRONCS CORPORATION
This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
Service Headquarters: Sharp Plaza, Mahwah, New Jersey, 07430-2135
R-419CK
This is a supplemental Service Manual for Microwave Oven model R-419CK. This model is quite similar to the base
model R-420CK (S/M# S49M132R420CE).
This supplemental manual must be used in conjunction with the base model service manual for complete operation,
service, safety and replacement parts information.
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - SUPPLEMENTAL SERVICE MANUAL

R-419CKIn the interest of user-safety the oven should be restored to its originalcondition and only parts identical to those specified should be used.

Página 2 - BEFORE SERVICING

8R-419CK6. Re-install the outer case (cabinet).7. Reconnect the power supply cord after the outer case is installed.8. Run the oven and check all func

Página 3 - WARNING TO SERVICE PERSONNEL

9R-419CKTEST PROCEDURESPROCEDURELETTERCOMPONENT TESTChecking the initial sensor cooking conditionWarning: The oven should be fully assembled before fo

Página 4

10R-419CKCHECKING CONTROL UNIT(1) Disconnect the power supply cord, and then remove outer case.(2) Open the door and block it open.(3) Discharge high

Página 5 - SERVICE MANUAL

11R-419CK645123645123ABCDEFGHABCDEFGHFigure S-1. Pictorial DiagramHIGH VOLTAGECAPACITORHIGH VOLTAGEWIRE AH.V. RECTIFIERPOWER SUPPLY CORD 120V 60HzHIGH

Página 6 - GENERAL INFORMATION

12R-419CK645123645123ABCDEFGHABCDEFGHFigure S-3. CPU Unit Circuit

Página 7 - OVEN DIAGRAM

13R-419CKREF. NO. PART NO. § DESCRIPTION Q'TY CODEPARTS LISTNote: The parts marked “∆” may cause undue microwave exposure.The parts marked “*” ar

Página 8 - OPERATION

14R-419CKREF. NO. PART NO. § DESCRIPTION Q'TY CODE4- 6 NFANPB001MRE0 M Fan blade 1 AC4- 7 PDUC-B088MRF0 M Fan duct 1 AC4- 8 ------------ M Oven

Página 9

15R-419CK645123645123ABCDEFGHABCDEFGHOVEN AND CABINET PARTS2-34-76-71-54-64-84-96-56-42-17-61-124-107-27-27-54-31-137-37-61-97-87-84-27-51-111-31-47-4

Página 10 - TEST PROCEDURES

16R-419CK645123645123ABCDEFGHABCDEFGHCONTROL PANEL PARTS5-15-1-25-1-15-35-45-55-2Actual wire harness may be different from illustration.6-36-26-1DOOR

Página 11

17R-419CKPACKING AND ACCESSORIESDOOR PROTECTION SHEETPLASTIC BAGPACKING CASETOP PAD ASSEMBLYINTO THE OVEN CAVITY6-5 TURNTABLE TRAY6-4 TURNTABLE SUPP

Página 12

R-419CKPRECAUTIONS TO BE OBSERVED BEFORE ANDDURING SERVICING TO AVOID POSSIBLEEXPOSURE TO EXCESSIVE MICROWAVEENERGY(a) Do not operate or allow the ove

Página 13 - Figure S-1. Pictorial Diagram

18R-419CK'2000 SHARP CORP. (1M3.20E) Printed in U.S.ACOPYRIGHT © 1999 BY SHARP CORPORATIONALL RIGHTS RESERVED.No part of this publication may be

Página 14 - Figure S-3. CPU Unit Circuit

1R-419CKWARNING TO SERVICE PERSONNELMicrowave ovens contain circuitry capable of pro-ducing very high voltage and current, contact withfollowing parts

Página 15 - PARTS LIST

2R-419CKMICROWAVE MEASUREMENT PROCEDUREA. Requirements:1) Microwave leakage limit (Power density limit): The power density of microwave radiation emit

Página 16

3R-419CKSHARP ELECTRONICS CORPORATIONSHARP PLAZA, MAHWAH,NEW JERSEY 07430-2135SERVICE MANUALMICROWAVE OVENR-419CKFOREWORDThis Manual has been prepared

Página 17

4R-419CKITEM DESCRIPTIONPower Requirements 120 Volts / 13.3 Amperes/1550Watts60 HertzSingle phase, 3 wire groundedPower Output 1100 watts (IEC-705 TES

Página 18

5R-419CKa qualified electrician and have it replaced with a properly groundedthree-pronged wall receptacle or have a grounding adapter properlygrounde

Página 19 - PACKING AND ACCESSORIES

6R-419CK SENSOR COOKING CONDITIONUsing the SENSOR function, food is cooked without figuringtime, power level or quantity. When the oven senses enoug

Página 20

7R-419CKFigure O-2 Oven Schematic - Cooking ConditionFigure O-1 Oven Schematic - Off ConditionSCHEMATICNOTE: CONDITION OF OVEN1. Door Closed2. CLOCK